E1022
240 x 64 pixel monochrome keypad HMI
- 240 x 64 pixels
- FSTN display
- 240 x 64 pixels
- Project storage 512KB
- Operating temperature 0 to +50 °C
- Serial, Enet w/Exp module
- 6 keys / 6 LEDs
Important life cycle dates, read more -> Contact Print (PDF)
Facts
General description
Part number | 603111202 |
Life cycle status | Limited |
Warranty | 1 year |
Mechanical
Mechanical size | 155 x 155 x 52.4 mm |
Cut-out size | 120 x 138 mm |
Weight | 0.55 kg |
Housing material | Powder-coated aluminium, grey |
Power
Input voltage | 20 - 30 V DC |
Power consumption (max) | 2.4 W |
Input fuse | Internal DC fuse, 1.0 AT |
Display
Size diagonal | 240 x 64 pixels |
Resolution | 240 x 64 pixels |
Backlight | LED with dimming |
Backlight life time | 47.000 hrs |
Display type | Monochrome FSTN |
Serial communication
Number of serial ports | 1 Port 9pin DSUB/1 Port 25 pin DSUB |
Serial port 1 | RS 232 (RTS/CTS) |
Serial port 2 | RS422 (RTS)/RS485 |
Resources
Manuals
File name | Date | |
---|---|---|
CAN J1939 Expansion Module for iX and EXTER/E1000 Operator Panels (MAEN962/MADE962) | 2022-10-10 08:57:41 |
Drawings
Cable guide
Certificates
File name | Date | |
---|---|---|
ABS EXTER/E1000 Series Marine Certificate | 2022-10-10 09:04:07 | |
Certificate of Compliance for EXTER and E1000 UL1604/508/60950-1 | 2022-10-10 09:04:07 | |
E1000 DNV Certification | 2022-10-10 09:04:35 | |
EXTER E1000 ABS PDA Certification 14-LD356481-1-PDA (PROD CERT - 1032465 - 1 - A1) - 1 | 2022-10-10 09:04:27 | |
EXTER E1000 DoC CE, RoHS | 2022-10-10 09:04:28 | |
Germanischer Lloyd Marine Approval for EXTER/E1000 Series (new 2013) | 2022-10-10 09:04:27 | |
Green Passport EXTER/ E1000 | 2022-10-10 09:04:21 | |
Trade compliance Exter- / E1000-series, PI00137 | 2022-12-12 11:33:02 |
Knowledge
Product information
File name | Date | |
---|---|---|
iX_EXTER_E1000_Environmental | 2022-10-10 08:40:17 | |
PCN E1000 remove coating on CPU and Power board (PDM_CDOC - 1030026 - 1 - A1) - 1 | 2022-10-10 09:08:07 | |
Release Notes EXTER/E1000 post 1.52 release | 2022-10-10 09:07:58 |
Software
File name | Date | |
---|---|---|
Remote Access Viewer v1.5.4, for Exter/E1000 - TxA/TxB/TAxx - X2 panels | 2023-08-28 08:26:38 |
Find a replacement for your existing EXTER/E1000 panel in this table!
CAN J1939 Expansion Module for iX and EXTER/E1000 Operator Panels (MAEN962/MADE962)
The expansion module is used for the operator panel to communicate via CAN J1939. The correct driver must be installed in the operator panel.
CAB15: CANopen Adapter. CIMREX and EXTER / E- and E1000 Series. RS422
The adapter is easily mounted in the RS422 interface on the operator panel . Should the installation space limit the possibility to plug in the adapter directly on the back of the operator panel, simply use the optional bracket and connector cable to mount the adapter in a more convenient location (up to 1.5 meters from the panel).
CAB12: 9-Pin Male/Female D-Sub Adapter. EXTER / E1000 Series to CIMREX / E- Series Cables RS232
CAB11: MPI Adapter between Siemens S7 and CIMREX and EXTER / E- and E1000 Series MPI to RS232
CAB11 to CIMREX: Use cable assembly CAB5
CAB11 to EXTER: Use cable
assembly CAB5 and CAB12 adapter in EXTER connector
Overview panels via
MPI: See drawing 5409K
Outline CAB11: See drawing 3359K
CAB6: CIMREX and EXTER / E- and E1000 Series to PC/PC-Compatible. RS422
Allen-Bradley ControlLogix to CIMREX and EXTER / E- and E1000 series
B&R 2000 series (Mininet) to CIMREX and EXTER / E- and E1000 series
PC to CIMREX and EXTER / E- and E1000 series
Siemens Simatic
S7-300/400 to CIMREX and EXTER / E- and E1000 series
03338: Idec Micro to CIMREX and EXTER / E- and E1000 Series via CAB8. Screw Connectors. RS422
03334: Toshiba PROSEC T-Series to CIMREX and EXTER / E- and E1000 Series with CAB12. RS232
03342: Koyo DL-Series to CIMREX and EXTER / E- and E1000 Series with CAB12. DB9 to DB15. RS232
03332: Control Techniques Unidrive to CIMREX and EXTER / E- and E1000 Series Point-to-Point. RS422
03330: Control Techniques Unidrive to CIMREX and EXTER / E- and E1000 Series via CAB8. RS422
03343: Koyo DL-Series to CIMREX and EXTER /E- and E1000 Series with CAB12. RJ12 to DB9F. RS232
05273: Cable Adapter for CIMREX and EXTER / E- and E1000 Series to Old Cable Assembly for MAC50/90/200. RS422
05236: Mitsubishi A1SJ71C24-R2 or A1SJ71QC24 or A1SJ71UC24-R2 or QJ71QC24 to EXTER / E1000 Series. RS232
CAB30: Programming Cable EXTER / E1000 Series. RS232
Allen-Bradley ControlLogix / SLC 5 / SLC 500 to EXTER / E1000 series
B+R 2000 series (Mininet) to EXTER / E1000 series
Mitsubishi
FX1N/FX2N-232BD to EXTER / E1000 series
PC to EXTER / E1000 series
("Programming cable")
Siemens S7-300/400 to EXTER / E1000 series
CAB10: Allen-Bradley SLC5 and 500 to CIMREX and EXTER / E- and E1000 Series RS485 to RS422
CAB6 Cable assembly. E- and E1000-series to PC/PC-compatible port. RS-422 to RS-232
B+R 2000 series (Mininet) to E- and E1000-series operator panel
PC to E- and E1000-series operator panel
Siemens Simatic S7-300/400 to E- and E1000-series operator panel
CAB9: CIMREX and EXTER / E- and E1000 Series to Unit with RJ45 Connector. RS422
CIMREX and EXTER / E- and E1000 series to Mitsubishi FR-A/E/F/S
CIMREX
and EXTER / E- and E1000 series to Mitsubishi servo via MR-CN3 plug
CAB14 Cable assembly. Matsushita FPO/M/2/2SH to E-series or E1000-series with CAB12. RS-232
Cable assembly. Intelligent Actuator SuperSEL to E1000-series. Centronics25 to DB9F. RS-232, 05246K
CAB8 Adapter. E- and E1000-series to RS-485. RS-422 (4 wire) to RS-485 (2-wire)
05005 Communication ports E1000-series
RS-485 to E1000-series
SAIA PCD series to E1000-series
Siemens S7-200/300/400
05243 Cable assembly. SEW Eurodrive Movi .. to E- and E1000-series with CAB8. RS-485 (2-wire)
EXTER E1000 DoC CE, RoHS
ABS EXTER/E1000 Series Marine Certificate
ABS EXTER/E1000 series marine certificate
Certificate of Compliance for EXTER and E1000 UL1604/508/60950-1
Issue Date 2008 July 28
UL 508 - Industrial Control Equipment
UL 1604 - Electrical Equipment
for Use in Class I and II, Division 2, and Class III Hazardous
(Classified) Locations
UL 60950-1 - Information Technology Equipment
Germanischer Lloyd Marine Approval for EXTER/E1000 Series (new 2013)
Trade compliance Exter- / E1000-series, PI00137
Green Passport EXTER/ E1000
E1000 DNV Certification
E1000 DNV Certification
EXTER E1000 ABS PDA Certification 14-LD356481-1-PDA (PROD CERT - 1032465 - 1 - A1) - 1
E1000, Modbus master driver to Jokab Pluto (Safety PLC system)
Modbus addressering for example register 400.001 will give error message
"Illegal function Station 1"
Driver Modbus Master version 5.05.19
Solution
Adjust driver parameter "Force function code
0x10" to Enable
E1000 printer Form feed

Adressing in E1000




E1000 heartbeat in firmware 1.5 and 1.31 (and older)
Do the Tx (timeout) and Rx (retries) commands work for EXTER / E1000?
Does EXTER or CIMREX series / E1000 or E-series withstand acetone vapour?
You can find information about how the operator panels reacts to different solvents in the installation manuals. Regarding acetone, we recommend that you do not install an EXTER or CIMREX / E1000 or E-series panel in an enviroment where it will be exposed to acetone vapour.
Supported voltage and power peaks for E1000/Exter teminals
How to get the old Index functionality in E1000
When upgrading a project from E-series to E1000-series there is a difference between the Index functionality.
For example if I1 = 1
E-series
D0.0I1 -> D1.0
D0I1 (Signed 32-bit) -> D1 (Signed 32-bit)
E1000-series
D0.0I1 -> D0.1
D0I1 (Signed 32-bit) -> D2 (Signed 32-bit)
There is a possibility to get the old E-series behaviour in E1000-series if the driver being used is a v5 (generic) driver or most of the MELSEC drivers.
To get the old functionality two driver commands XFLINDEX and XBITINDEX has to be set.
E1000 alarm list size
E1000: CAB7 no longer available
Since the CAB7 is no longer available, the current work around is to change controller port in your HMI project to COM2 (RS-232).
Use the converter 6ES5 734-1BD20 from Siemens to connect the CPU port on the controller and the HMI via a 25 to 9-pin converter.
Communicate with a Siemens IM 151-8 PN/DP (ET200S) using E1000
Use the S7 ISO over TCP/IP driver in E1000.
E1000: Load project to terminal from USB memory
If the message "External memory card detected" is not displayed right away when inserting the USB stick, wait for 30 seconds.
E1000: Japanese characters
Customer uses font MSSONG.TTF and tested DejaVu.TTF for Japanese
characters, it looks good in the computer simulation but not on the E1032
panel.
ANSWER
Works in font "Arial Unicode MS" which indicates that MSSong and
DejaVu does not contain the character set that the customer has used.
Note that font "Arial Unicode MS" (Arialuni.ttf) it is about 22MB big
and can not be loaded to memory of an E1032, which is not possible to expand
the memory!
The memory must be expanded to cope with this font. Since the E1032 can not be
expanded, there must be a E1070 or higher.
Tested in the E1070 with 64MB memory card, works ok!
Settings in E1070:
E1000 Index system signals etc.



Problem with CF memory card detection in Exter/E1000 panels
- CF512 (art.no. 601000024) a 512MB Industrial Grade from Cactus Technologies, 0 to +70 gr C
- 4GB Industrial Grade
E1000 serien: ASCII-object and Unicode in E1000
E1000 pro+ Axis window white
E1000: Get the value 8224 in some registers when using Current Recipe register
E1000 and Siemens S7-1200
Is it possible to communicate to S7-1200 system with the E1000 terminals?
Yes, but in the driver properties you need to change the slot number to "1"
The S7-1200 has only one communication port- Profinet or TCP(Iso on TCP). With the driver S7-ISO over TCP the tests has been successful.
Internal memory card in E1000-series
How do you expand the memory capacity of a terminal E1000.
This is done by using a CompactFlash card (CF). To put this card in the
terminal assigned as needed. On the circuit board inside the terminal cover on
the back, there's a socket for inserting the CompactFlash card.
The project must also be set for an expanded internal memory expansion, meny
selection Configuration - Terminal ...
Enter the size of the memory card, see picture below:
Set Clock in E1000
To set the operator panel clock in E1000, a maneuverable Date/Time object (Digital clock) must be defined.
The mode switch (service meny) have only function for
Date/Time format.
Use two different VNC clients to the same E1000 panel
How to use two different VNC clients to the same E1000 panel?
It
is impossible to use two Remote Access at the same time with terminal.
Solution
The E1000 terminal could work with two
VNC clients (computers) one connected to the port 5800 in Remote Access,
and the other one connected to port 5900 in web mode. Test made with E1071
and E-Designer project, settings in Network Services.
E1000: Service menu, Load project to terminal
- From E-designer manual
2.7 Service Menu
The Service Menu is accessed by setting the mode switches on the operator
panel in mode 1000. Please see the Hardware and Installation manual for the
operator panel for information about the mode switches.
The following options are available in the Service Menu:
Network Settings
Select this option to access the Network
Menu.
Network Menu
The options in the Network Menu corresponds to
selecting Settings/Network in
E-Designer and contains the following
items:
Erase Project Memory
This option erases the project memory.
Load Project from Memory Card
An empty operator panel can be
started with an existing E-Designer project, used in
another panel. The
project first has to be saved to a Compact Flash memory card or
USB
memory stick via the function Save project to memory card (for example via a
function key).
Insert the memory card in the empty panel before
boot-up. Then select Load project
from memory card in the service menu
and follow the instructions.
Enter Transfer Mode
Allows entering transfer mode manually,
needed to download projects via GSM
modem. See section Transfer via GSM
Modem for details.
Not available for E1012 and
E1022.
Enter Run Mode
Allows entering run mode manually, needed to
download projects via GSM modem.
See section Transfer via GSM Modem for
details.
Menu item Described in
TCP/IP Settings 18.2 Network
Communication through Ethernet
Accounts 18.5 Network Accounts
Services 18.4 Network Services
Update System Program from Memory Card
Insert a Compact Flash
or USB memory stick with a new system program and follow
the
instructions. The system program can also be updated via the configuration
tool
for the operator panels.
Calibrate Touch Screen
Follow
the instructions on the screen to calibrate the touch screen.
23.5 Transfer to/from External Memory Card
Not available for E1012 and E1022.
Export Project to Memory Card
In order to export the project to a Compact Flash memory card or USB Flash
drive,
select Transfer/Export Project Transfer File. The output from the
export is a datfile.
Load Project from Memory Card
Save the dat-file to the library BACKUP/PROJECTS on the external memory
card.
The file structure is automatically created when formatting the card
in the operator panel. If no operator panel is available, the library structure
must be created manually. A function or touch key can be configured in the
configuration tool to download the
operator panel project, by selecting
the function Loads project from memory card. See also chapter Function Keys.
The command MCI can be used to indicate that a memory card is used in the
panel. Type MCIx on the Commands line by selecting Setup/System Signals. x
represents the digital signal that will be set when a memory card is
inserted.
________________________________________________________________________
How to read the project from USB
- USB memory into the terminal
- Switch 1:ON
- Power ON
- Select Load From memory Card - select project
- Power OFF (< 5sec)
- Switch 1: OFF
- Power ON
- The terminal start up and read the file and restart.
________________________________________________________________________
E1000 Password on USB key

E1000 OEM loader when using EEPROM
iX_EXTER_E1000_Environmental
PCN E1000 remove coating on CPU and Power board (PDM_CDOC - 1030026 - 1 - A1) - 1
Release Notes EXTER/E1000 post 1.52 release
Release information about changes after the 1.52 release
PIEN173E includes the EXTER panels
PI00175E includes the E1000 panels
Remote Access Viewer v1.5.4, for Exter/E1000 - TxA/TxB/TAxx - X2 panels
Remote Access Viewer is a program for remote access and control Exter/E1000 - TxA/TxB/TAxx - X2 panels.
It is possible to access, reflect and control panels
from a PC by using the VNC client program, Remote Access Viewer (freeware),
together with the built-in VNC server (Remote Access function) in the iX
Panels.
NB: Even though the help file suggests another key combination, please note that Ctrl-Alt-Shift-F toggles Full screen mode on / off best, so you Restore from Fullscreen mode with this key combination!