EXTER T100 bl
10'' graphic touch HMI
- 800 x 600 pixels
- TFT display
- 10" TFT-LCD touch screen
- Project storage 12 MB
- Operating temperature 0 to +50 °C
- Ethernet and serial
- Black frame
Important life cycle dates, read more -> Contact Print (PDF)
Facts
General description
Part number | 602220034 |
Life cycle status | Limited |
Warranty | 1 year |
Mechanical
Mechanical size | 302 x 228 x 64 mm |
1 million finger touch operations | |
Touch type | Resistive type |
Cut-out size | 265 x 206 mm |
Weight | 2.1 kg |
Housing material | Powder-coated aluminium, grey |
Power
Input voltage | 20 - 30 VDC |
Power consumption (max) | 12 W |
Input fuse | Internal DC fuse, 3.15 AT |
Display
Size diagonal | 10.4 inch |
Resolution | 800 x 600 pixels |
Backlight | CCFL with dimming |
Backlight life time | 50,000 hrs |
Backlight brightness | 350 cd/m2 |
Display type | TFT CCFL |
Serial communication
Number of serial ports | 1 Port 9pin DSUB/1 Port 25 pin DSUB |
Serial port 1 | RS 232 (RTS/CTS) |
Serial port 2 | RS422 (RTS)/RS485 |
Ethernet communication
Number of Ethernet ports | 1 |
Ethernet port 1 | 1x10/100 Base-T (shielded RJ45) |
Resources
Manuals
File name | Date | |
---|---|---|
CAN J1939 Expansion Module for iX and EXTER/E1000 Operator Panels (MAEN962/MADE962) | 2022-10-10 08:57:41 |
Drawings
Cable guide
File name | Date | |
---|---|---|
05244: SEW Eurodrive Movi .... to EXTER / E1000 Series. RS485 | 2022-11-07 12:01:35 | |
CAB9: CIMREX and EXTER / E- and E1000 Series to Unit with RJ45 Connector. RS422 | 2022-09-15 12:23:22 |
Certificates
Knowledge
Program examples/Quickstarts
File name | Date | |
---|---|---|
Communication between EXTER and Honeywell HC900 controller | 2022-10-17 12:54:18 | |
Configuration of a modem PPP connection between EXTER and a PC with Windows XP (KI00251) | 2022-10-17 12:54:38 | |
Converting a CIMREX Project to EXTER (KI00256) | 2022-09-08 16:47:41 | |
Downloading Projects in the EXTER Operator Panels (SUEN264) | 2022-10-10 11:45:14 | |
EXTER Demo Projects | 2022-10-11 15:30:41 | |
Web Functionality in the EXTER Operator Panels | 2022-10-10 11:45:06 |
Information document
File name | Date | |
---|---|---|
Environmental Impact Report for iX Panels and EXTER Operator Panels (PIEN144C) | 2022-10-10 08:57:25 | |
Optimizing Your EXTER Project in Information Designer | 2022-09-08 16:53:53 |
Product information
File name | Date | |
---|---|---|
iX_EXTER_E1000_Environmental | 2022-10-10 08:40:17 | |
PCN EXTER remove coating on CPU and Power board (PDM_CDOC - 1030026 - 1 - A1) - 1 | 2022-10-10 09:08:03 | |
Release Notes EXTER/E1000 post 1.52 release | 2022-10-10 09:07:58 |
Software
File name | Date | |
---|---|---|
Remote Access Viewer v1.5.4, for Exter/E1000 - TxA/TxB/TAxx - X2 panels | 2023-08-28 08:26:38 |
Find a replacement for your existing EXTER/E1000 panel in this table!
CAN J1939 Expansion Module for iX and EXTER/E1000 Operator Panels (MAEN962/MADE962)
The expansion module is used for the operator panel to communicate via CAN J1939. The correct driver must be installed in the operator panel.
CAB15: CANopen Adapter. CIMREX and EXTER / E- and E1000 Series. RS422
The adapter is easily mounted in the RS422 interface on the operator panel . Should the installation space limit the possibility to plug in the adapter directly on the back of the operator panel, simply use the optional bracket and connector cable to mount the adapter in a more convenient location (up to 1.5 meters from the panel).
CAB12: 9-Pin Male/Female D-Sub Adapter. EXTER / E1000 Series to CIMREX / E- Series Cables RS232
CAB11: MPI Adapter between Siemens S7 and CIMREX and EXTER / E- and E1000 Series MPI to RS232
CAB11 to CIMREX: Use cable assembly CAB5
CAB11 to EXTER: Use cable
assembly CAB5 and CAB12 adapter in EXTER connector
Overview panels via
MPI: See drawing 5409K
Outline CAB11: See drawing 3359K
CAB6: CIMREX and EXTER / E- and E1000 Series to PC/PC-Compatible. RS422
Allen-Bradley ControlLogix to CIMREX and EXTER / E- and E1000 series
B&R 2000 series (Mininet) to CIMREX and EXTER / E- and E1000 series
PC to CIMREX and EXTER / E- and E1000 series
Siemens Simatic
S7-300/400 to CIMREX and EXTER / E- and E1000 series
Cable Guide for EXTER and CIMREX Operator Panels
Use this Excel document to get information about what cable to use when connecting an operator panel to a specific driver and other peripherals.
03338: Idec Micro to CIMREX and EXTER / E- and E1000 Series via CAB8. Screw Connectors. RS422
03334: Toshiba PROSEC T-Series to CIMREX and EXTER / E- and E1000 Series with CAB12. RS232
03342: Koyo DL-Series to CIMREX and EXTER / E- and E1000 Series with CAB12. DB9 to DB15. RS232
03332: Control Techniques Unidrive to CIMREX and EXTER / E- and E1000 Series Point-to-Point. RS422
03330: Control Techniques Unidrive to CIMREX and EXTER / E- and E1000 Series via CAB8. RS422
03343: Koyo DL-Series to CIMREX and EXTER /E- and E1000 Series with CAB12. RJ12 to DB9F. RS232
05273: Cable Adapter for CIMREX and EXTER / E- and E1000 Series to Old Cable Assembly for MAC50/90/200. RS422
05236: Mitsubishi A1SJ71C24-R2 or A1SJ71QC24 or A1SJ71UC24-R2 or QJ71QC24 to EXTER / E1000 Series. RS232
CAB30: Programming Cable EXTER / E1000 Series. RS232
Allen-Bradley ControlLogix / SLC 5 / SLC 500 to EXTER / E1000 series
B+R 2000 series (Mininet) to EXTER / E1000 series
Mitsubishi
FX1N/FX2N-232BD to EXTER / E1000 series
PC to EXTER / E1000 series
("Programming cable")
Siemens S7-300/400 to EXTER / E1000 series
CAB10: Allen-Bradley SLC5 and 500 to CIMREX and EXTER / E- and E1000 Series RS485 to RS422
EXTER K100 / E1100 Panel Cut-Out (pdf and dwg)
EXTER K100 / E1100 Outline Drawing (pdf and dwg)
EXTER K60 / E1060 Panel Cut-Out (pdf and dwg)
EXTER K70 / E1070 Panel Cut-Out (pdf and dwg)
CAB9: CIMREX and EXTER / E- and E1000 Series to Unit with RJ45 Connector. RS422
CIMREX and EXTER / E- and E1000 series to Mitsubishi FR-A/E/F/S
CIMREX
and EXTER / E- and E1000 series to Mitsubishi servo via MR-CN3 plug
DNV for EXTER Operator Panels
DNV (Det Norske Veritas) certification for EXTER operator panels
- EXTER DNV certificate 2011-2012 PIEN288.pdf
- EXTER DNV certificate extended vibration 2011-2012 PIEN289.pdf
- EXTER DNV Type Approval Certificate 2013-2014.pdf
- EXTER DNV Type Approval Certificate 2015-2016(PROD CERT - 1016729 - 1 - A2) - 1.pdf
- EXTER K10m, K20m, T70, T100 DNV Type Approval Certificate 2015-2016 (PROD CERT - 1016730 - 1 - A2) - 1.pdf
- EXTER K10m, K20m, T70, T100 DNV vibration class B Type Approval 2013-2014.pdf
EXTER E1000 DoC CE, RoHS
CCS - China Classification Society of EXTER and iX Panel PIEN287
Manufacturer's Declaration: ABS for EXTER-bl and EXTERsr-bl
Manufacturer's declaration ABS for EXTER-bl and EXTERsr-bl
IACS E10 for EXTER-bl Operator Panels
International Association of Classification Societies: E10 - Test
Specification.
EXTER T70-bl, EXTER T100-bl, EXTER T150-bl.
Declaration of Conformity CE for EXTER-bl and EXTERsr-bl
Declaration of Conformity CE for EXTER-bl and EXTERsr-bl
Declaration of Conformity CE for EXTER-bl
Declaration of Conformity CE for EXTER-bl
Declaration of Conformity ABS for EXTER-bl and EXTERsr-bl
Declaration of conformity ABS for EXTER-bl and EXTERsr-bl
UL E192000 for X2Base ,TxA, Exter
UL E192000 for X2Base ,TxA, Exter
ABS EXTER/E1000 Series Marine Certificate
ABS EXTER/E1000 series marine certificate
Certificate of Compliance for EXTER and E1000 UL1604/508/60950-1
Issue Date 2008 July 28
UL 508 - Industrial Control Equipment
UL 1604 - Electrical Equipment
for Use in Class I and II, Division 2, and Class III Hazardous
(Classified) Locations
UL 60950-1 - Information Technology Equipment
Environmental Impact Report for EXTER Operator Panels (PIEN144B)
K10m, K20m, K30m, K60, K60c, K60m, K70, K100, T40, T40m, T60c, T60c, T60m, T70, T100, T150
Compass Safe Distance for EXTER Operator Panels (PIEN168A)
SP Swedish Testing and Researh Institute has tested the EXTER operator panels for determination of compass safe distance. This document lists the results for each operator panel model.
Germanischer Lloyd Marine Approval for EXTER/E1000 Series (new 2013)
Russian Maritime Register of Shipping for EXTER Operator Panels
Russian Maritime Register of Shipping (RS) certificate for EXTER operator panels
Trade compliance Exter- / E1000-series, PI00137
Green Passport EXTER/ E1000
RINA for EXTER Operator Panels
RINA certification ELE198008CS for EXTER operator panels of 2008-04-18
Cyclic Salt Mist EXTER T70, EXTER T100, EXTER T150 EMC
Manufacturer's declaration of conformity for the standards regarding Cyclic
salt mist IEC 60068-2-52.
The file T70_T100_T150_EMC_Cyclic salt
mist_06010_06030_06050.pdf refers to type no. 06010/06030/06050.
EXTER E1000 ABS PDA Certification 14-LD356481-1-PDA (PROD CERT - 1032465 - 1 - A1) - 1
EAR Approval for the EXTER Operator Panels
EAR- Export Administration Regulation.
US Authorities approval for
panels based on EXTER platforms due to the encryption technologies in Windows
CE and the X-scale processor. Valid for all EXTER panels
Classification:
EAR99
CCATS#: G049136
IACS E10 for EXTER Operator Panels
International Association of Classification Societies: E10 - Test
Specification.
EXTER K10m, EXTER K20m, EXTER K30m, EXTER T40/T40m, EXTER
T60c/T60m, EXTER K60c, EXTER T70, EXTER K70, EXTER T100, EXTER K100, EXTER
T150.
Declaration of Conformity for EXTER Operator Panels
Date: 2009-04-17
NEMA 4X for EXTER Operator Panels
Manufacturer's declaration of conformity with NEMA 4X - indoor use only.
EXTER K10m, EXTER K20m, EXTER K30m, EXTER K60c, EXTER K70, EXTER K100, EXTER T40/T40m, EXTER T60c/T60m, EXTER T70, EXTER T100, EXTER T150
For details on tests and certificates for the operator panel, please see the document "Hardware tests and certificates" (PIEN182).
MTBF (Mean Time Between Failures) for EXTER Operator Panels
The documents include the results of the MTBF calculations for the
individual EXTER panels. The document "What is MTBF" gives a little background
and information about the concept.
MTBF for EXTER K30m, EXTER K60c, EXTER
K70, EXTER K100, EXTER T40/T40m, EXTER T60c/T60m, EXTER T70, EXTER T100, EXTER
T150
Do the Tx (timeout) and Rx (retries) commands work for EXTER / E1000?
Does EXTER or CIMREX series / E1000 or E-series withstand acetone vapour?
You can find information about how the operator panels reacts to different solvents in the installation manuals. Regarding acetone, we recommend that you do not install an EXTER or CIMREX / E1000 or E-series panel in an enviroment where it will be exposed to acetone vapour.
Does the Tx (timeout) and Rx (retries) command work for EXTER?
Supported voltage and power peaks for E1000/Exter teminals
E1032/Exter K30: Terminal reboot when changing blocks
Cables : Cable to connect EXTER to a PC
The cable you need is a CAB30, you find the drawing attached.
The pin out for the terminal is described in the installation manual.
Battery (MS614S) in EXTER K10m and EXTER K20m / E1012 and E1022
Worst case: If it takes more than 40 weeks between delivering terminal from factory to installation, the battery is discharged.
The intention is that the battery not will have to be replaced during the lifetime of the terminal.
Problem with CF memory card detection in Exter/E1000 panels
- CF512 (art.no. 601000024) a 512MB Industrial Grade from Cactus Technologies, 0 to +70 gr C
- 4GB Industrial Grade
Operating temperature testing for EXTER
Exter panels are tested for temperatures between 0 and 40 or 50 degree C depending on the mounting conditions.
PPP with Exter and GSM modems
Problem to printout text strips on EXTER K100
Which material will be used for the EXTER adapter plates?
Driver MELSEC QnA/Q-C24: What settings are needed in QC24 to be to communicate with an EXTER?
Downloading Projects in the EXTER Operator Panels (SUEN264)
This document describes different ways to download an Information Designer project to an EXTER operator panel.
Communication between EXTER and Honeywell HC900 controller
HC900 is a Hybrid Controller developed by the company Honeywell and is used mostly in the process industry. The HC900 use Modbus TCP and RTU as communication protocol to external devices such as HMI.
Configuration of a modem PPP connection between EXTER and a PC with Windows XP (KI00251)
This document describes how to configure a modem PPP connection between a
PC with Windows XP and an EXTER operator panel using the RS232C/RS422 port.
A PPP-connection can for example be used to:
Download and upload
of projects
FTP Server Access
Remote Access view
WWW Server
The document is available in English and Traditional Chinese.
EXTER Demo Projects
The demo projects contain all basic features of the EXTER operator panels and serve as a good start for learning about the EXTER series.
Touch Panel |
Key Panel |
Mobile Panel |
EXTER T150 |
||
EXTER T100 | EXTER K100 | |
EXTER T70 | EXTER K70 | EXTER M70 |
EXTER T60 | EXTER K60 | |
EXTER T40 | ||
EXTER K30 | ||
EXTER K20 | ||
EXTER K10 |
- Demo_K100_ver_1.30.zip
- Demo_K10m_ver_1.40.zip
- Demo_K20m_ver_1.40.zip
- Demo_K30m_ver_1.30.zip
- Demo_K60c_ver_1.30.zip
- Demo_K70_ver_1.30.zip
- Demo_M70_ver_1.40.zip
- Demo_T100_ver_1.30.zip
- Demo_T150_ver_1.30.zip
- Demo_T40_ver_1.30.zip
- Demo_T40m_ver_1.30.zip
- Demo_T60c_ver_1.30.zip
- Demo_T60m_ver_1.30.zip
- Demo_T70_ver_1.30.zip
Web Functionality in the EXTER Operator Panels
The document includes tips on how to configure the built-in web functions in the EXTER panels.
Converting a CIMREX Project to EXTER (KI00256)
CIMREX projects can be converted to EXTER, in order to run the project on
the new hardware, and to take advantage of the new features in Information
Designer.
Converting a project saves time compared to configuring
a new project from scratch, and the converted project will be ready to use
right away.
SUTW256 is in Traditional Chinese
Environmental Impact Report for iX Panels and EXTER Operator Panels (PIEN144C)
The following products are included:
iX Panel T40
iX Panel T60
iX Panel T70
iX Panel T100
iX
Panel T150
EXTER K10m
EXTER K20m
EXTER K30m
EXTER K60
EXTER
K60c
EXTER K60m
EXTER K70
EXTER K100
EXTER T40
EXTER
T40m
EXTER T60
EXTER T60c
EXTER T60m
EXTER T70
EXTER
T100
EXTER T150
Optimizing Your EXTER Project in Information Designer
The document includes tips on how to optimize your EXTER project to maximize the efficiency of your installation.
iX_EXTER_E1000_Environmental
PCN EXTER remove coating on CPU and Power board (PDM_CDOC - 1030026 - 1 - A1) - 1
Release Notes EXTER/E1000 post 1.52 release
Release information about changes after the 1.52 release
PIEN173E includes the EXTER panels
PI00175E includes the E1000 panels
Remote Access Viewer v1.5.4, for Exter/E1000 - TxA/TxB/TAxx - X2 panels
Remote Access Viewer is a program for remote access and control Exter/E1000 - TxA/TxB/TAxx - X2 panels.
It is possible to access, reflect and control panels
from a PC by using the VNC client program, Remote Access Viewer (freeware),
together with the built-in VNC server (Remote Access function) in the iX
Panels.
NB: Even though the help file suggests another key combination, please note that Ctrl-Alt-Shift-F toggles Full screen mode on / off best, so you Restore from Fullscreen mode with this key combination!
vncviewer.exe_patch.zip contains a patched vncviewer.exe