Facts
General description
Part number | 630009810 |
Life cycle status | Active |
Warranty | Up to 2 years |
Certifications
General | CE, FCC, UL 61010-2-201 |
Safety | UL 61010-1, UL 61010-2-201, CAN/CSA-C22.2 No. 61010-1, CAN/CSA-C22.2 No. 61010-2-201 |
Mechanical
Mechanical size | 409 x 270 x 43mm |
Panel Mount | |
1million finger touch operations | |
Touch type | Resistive |
Cut-out size | 393 x 254mm |
Weight | 2.46 kg |
Housing material | Plastic (PC+ABS), Gray |
Buzzer | No |
LED | No |
Power
Input voltage | 24 V DC (18 to 32 VDC) CE: The power supply has to be conform with the requirements according to IEC 60950 and IEC 61558-2-4.UL and cUL: The power supply has to be conform with the requirements for class II power supplies. |
Power consumption (max) | 17.8 W |
Input fuse | Internal DC fuse |
Hardware platform | X2 base v2 |
CPU | ARM Cortex A8 1000MHz |
RAM | 512 MB |
FLASH | 2 GB |
Display
Size diagonal | 15.6" diagonal |
Resolution | 1366 × 768 pixel (16:9) |
Backlight | LED Backlight |
Backlight life time | 50000 hours |
Backlight brightness | 300 cd/m² |
Backlight dimming | Industrial Dimming |
Display type | TFT-LCD with LED backlight |
Digtal IO
Digital output | No |
Serial communication
Number of serial ports | 2port9pinDsub, 1port3pinScrew |
Serial port 1 | RS 232 (RTS/CTS) |
Serial port 2 | RS422/485 |
Serial port 3 | RS 485 |
Serial port 4 | RS 232 |
Serial port 5 | RS422/485 |
Serial port 6 | RS 485 |
Ethernet communication
Number of Ethernet ports | 2 |
Ethernet port 1 | 1x10/100 Base-T (shielded RJ45) |
Ethernet port 2 | 1x10/100 Base-T (shielded RJ45) |
Expansion interface
Expansion port | No |
SD card | Yes |
USB | 2 |
Environmental
Operating temperature | -10°C to +50°C |
Storage temperature | -20°C to +60°C |
Shock | 15g, half-sine, 11ms according to IEC60068-2-27 |
Vibration | 1g, according to IEC 60068-2-6, Test Fc |
Sealing front | IP65, NEMA 4X/ 12 and UL 50E Type 4X/ 12 |
Sealing back | IP20 |
Humidity | 5% – 85% non-condensed |
Resources
Knowledge
File name | Date | |
---|---|---|
ARTI - 8bit data types not working | 2024-10-10 11:05:50 | |
Best Practice Database on SD card or flash memory | 2023-01-31 13:52:59 | |
Convert from Exter/E1000 To X2 Series | 2022-09-15 12:32:35 | |
Creating a custom Welcome screen / Startup screen on a X2 operator panel | 2024-11-07 14:26:33 | |
Driver MODICON Modbus Slave: Command XDNCW | 2022-11-22 20:19:01 | |
How to download Free software packages from SmartStore | 2025-05-08 10:17:08 | |
Image Sticking | 2022-11-21 15:55:49 | |
iX - SMTP - Using Gmail servers using App password | 2022-12-13 15:15:01 | |
iX Developer SP7 - 2.47.473 Release information | 2022-10-10 16:34:05 | |
Max number of recipe items / tags | 2022-09-15 12:37:24 | |
OPC ua settings in Phoenix plxnext engineer | 2024-08-23 11:54:55 | |
Windows CE versions, X2, iX, E1000 | 2022-10-07 14:47:15 | |
X2 image - Update EBOOT require SD card to be formatted to FAT16/FAT32 | 2022-09-22 15:36:01 |
Product information
File name | Date | |
---|---|---|
Battery test summary - X2 base, Y2 base v2, BoX2 base v2, C2 industrial PCs | 2024-02-28 10:01:41 | |
MTBF Summary X2 base v2 | 2025-01-08 11:23:49 | |
X2 export control and dual use | 2023-02-08 14:48:11 | |
X2 Letter of Volatility | 2023-04-28 09:39:15 |
Certificates
File name | Date | |
---|---|---|
CE certificate x2 base 15 v2 HP | 2022-10-21 13:15:25 | |
CE Manufacturer declaration X2 base v2 | 2022-10-10 12:34:59 | |
DoC battery X2 base (V2) | 2024-08-02 14:16:03 | |
DoC ECCN for X2 series HMI | 2024-03-18 17:18:35 | |
Environmental Impact Report X2 pro, X2 marine, X2 control, X2 motion | 2022-09-22 13:52:27 | |
FCC certificate x2 base 15 v2 HP | 2022-10-21 13:15:26 | |
KCC certificate X2 base 15 v2 HP | 2022-10-21 13:15:27 | |
Manufacturer declaration: X2 base v2 UKCA Declaration of Conformity | 2022-11-08 09:23:45 | |
RoHS and REACH Declaration of Conformity | 2025-03-25 16:43:31 | |
SDoC Green Passport | 2022-09-22 13:49:43 |
Drawings
File name | Date | |
---|---|---|
3D drawing X2 base 15 v2 HP | 2022-10-21 13:14:55 | |
Cable CAB113: Cable for ModBus RS485 between X2 panel and BFI | 2022-10-05 14:15:53 | |
Outline drawing X2 base 15 v2 HP | 2022-10-21 13:15:20 |
Program examples/Start-up
Manuals
File name | Date | |
---|---|---|
Installation manuals X2 base 15 v2 HP, MAEN333 | 2023-06-28 11:07:43 | |
iX Developer Reference Manual, MAEN355 rev. B (current version) | 2023-09-19 14:12:01 | |
X2 base / pro / extreme / marine / control - Configuration and Image manual , MAEN352 rev B | 2024-05-07 13:28:37 | |
X2 base V2 Serial interface mapping | 2022-09-22 15:32:44 |
Information document
File name | Date | |
---|---|---|
Environmental report X2 base v2 | 2022-10-21 13:14:18 | |
Guidelines for TxA and TxB migration to X2. | 2022-10-10 08:38:10 |
Drivers
Software
File name | Date | |
---|---|---|
Remote Access Viewer v1.5.4, for Exter/E1000 - TxA/TxB/TAxx - X2 panels | 2023-08-28 08:26:38 | |
SqlProxy - Connects iX Panels transparently to SQL Server | 2023-06-07 16:02:43 |
Configuration files
Brochures
File name | Date | |
---|---|---|
X2 brochure (English), BREN631 | 2022-09-21 08:11:56 | |
X2 brochure (Spanish) | 2022-09-21 08:12:32 | |
X2 brochure 2019 (French) | 2024-01-15 10:52:15 | |
X2 series (German) | 2022-09-21 08:11:38 | |
X2 starterkit DE | 2022-10-10 11:03:21 |
System program
File name | Date | |
---|---|---|
X2 base v2 (HP) 1.0.2 b280 | 2022-09-22 15:31:45 | |
X2 base V2 1.1 (Current version) | 2022-06-27 11:46:19 | |
X2 base v2 image V2.2 b1041 (Current version) | 2023-08-24 16:12:11 | |
X2 series Custom Welcome Screen (splash), template | 2025-04-23 14:37:50 |
Smart Engineering Resources
iX Developer SP7 - 2.47.473 Release information
Driver MODICON Modbus Slave: Command XDNCW
Creating a custom Welcome screen / Startup screen on a X2 operator panel
X2 series
It's possible to create a custom Welcome Screen / startup screen, this is described in detail in the Configuation and Image manual:
X2 Configuration and Image manual
iX - SMTP - Using Gmail servers using App password
Google has dropped the support for "less secure apps" and no longer supports the use of third-party apps or devices which ask you to sign in to your Google Account using only your username and password.
From now on an "App Password" is required when sending emails from iX panels that are configured to use Gmail's SMTP servers. Please notice that 2 step verification is required in order to create an app password.
Create and use App Password
- Login to you Google account.
- Make sure 2-Step Verification is enabled.
- Generate an App password. Select "Mail" as app and for device select "Other" and enter a custom name. Click Generate to get an app password.
- Then use the following settings for the email device in the iX application
From Email Address: [Gmail address]
SMTP Server: smtp.gmail.com
Port: 587
Encryption Mode: ExplicitSSL
Authentication Mode: AuthLogin
Username: [Gmail address]
Password: [The App Password]
How to download Free software packages from SmartStore
This document provides guidelines for customers when downloading free software and firmware packages from SmartStore. These procedures are described:
ARTI - 8bit data types not working
ARTI driver 4.16.05
Normally the use of 8bit data types is supported if the option "Load symbols when connecting" = TRUE.
With version 4.16.05 the driver will constantly report "Datatype mismatch" if any kind of 8bit datatype, defined in the controller, is in use.
Workaround:
- Use the previous driver 4.15.04
- Change the datatype in the controller to 16bit
Extract from driver help.
OPC ua settings in Phoenix plxnext engineer
04 october 2022
To use IX OPC client with Phoenix PLC's some settings are needed in the PLxnext engineering tool, and also the PLC Webserver:
Basic settings "Visibility of variables" = "Marked"
Subject1 = HMI ip adress
UNcheck "Use the thruststore for client authentication" AND " Check application URI against client certificate.
To get the NS ( namespace ) settings in IX developer correctly, the easiest way is to browse the Phoenix server from IX developer, by clicking the small down arrow at the right side of the "ADD" button in Tags, and select "Add tags from OPC server" . Then the nemespaces are set automaticly. Otherwise you can see them in the screenshot below:
WEB Server:
Disable Autentication in WBM in the PLC
Login with "admin" and the password on the plc lable
Image Sticking
When utilizing TFT LCD HMI panels in applications where a fixed or partially fixed image remains displayed on the screen for extended periods of time, users may experience a phenomenon referred to by the LCD industry as Image Sticking. Image Sticking - sometimes also called "image retention" or "ghosting"- is a phenomenon where a faint outline of a previously displayed image remains visible on the screen when the image is changed.
Image sticking can be caused by:
- Static images
- No Screensaver
- Sharp contrast transition (e.g. black / white)
- High ambient temperatures
- Use the screensaver functionality.
- Changing constantly between static and dynamic images
- Avoid excessive brightness differences between foreground and background elements
- Use colors with similar brightness
- Use complementary colors in follow-up images
Best Practice Database on SD card or flash memory
This document provides recommendations for how to setup and use the X2 HMI panel in the best way to reduce unnecessary wear on the flash memory.
For more information: Best Practice Image update for X2 pro, X2 marine and BoX2 pro 2.1 HF
Max number of recipe items / tags
iX developer 2.40 SP7
The help file states that maximum 256 recipe items can be used. This is wrong, maximum number of recipe items / tags / columns is 998.
When attemting to add more, iX will display a popup with an error message.
Convert from Exter/E1000 To X2 Series
The Mitsubishi E-Series hardware products and E-Designer software have been manufactured by Beijer Electronics for Mitsibishi for many years. In 2015, this partnership ended. Beijer-branded E1000 HMIs are now orderable directly through Beijer or one of its authorizated distributors. As your Mitsubishi terminals need to be replaced, Beijer provides a smooth transition by offering three paths:
Direct Replacement Path (E1000 panels) - A direct hardware and software replacement for most E1000 panels. The Beijer-branded E1000 panels are identical to the Mitsubishi-branded E1000 panels, only the rear labeling is different.
Direct Replacement Path (EXTER panels) - A direct mechanical drop-in hardware replacement is available for most E1000 products. The replacement products use your existing E-Designer applications after a simple project conversion to Information Designersoftware, a service offered by Beijer Technical Support
Upgrade Replacement Path (X2 panels) - Enhance your future HMI offering with modern X2 hardware and state-of-the-art iX Developer software including graphics, scripting, alarms, recipes, remote access and multiple communication drivers. iX Developer supports and integrated E-Designer to iX Developer project conversion feature (as well as Information Designer to iX Developer).
The following is a comparison chart of the older, discontinued E-series/CIMREX HMI panels to the current E1000/EXTER HMI panels, as well as the closest versions to Beijer''s latest X2 panels.
Discontinued | Discontinued | Current | Current | Adapter | Current |
E-Series Models1 | CIMREX Models2 | E-1000 Models3 | EXTER Models4 | Plate5 | X2 Models6 |
E50 | CIMREX 5 | n/a | n/a | n/a | n/a |
E100 | CIMREX 10 | E1012 | K10m | n/a | X2 base 5 |
| | | | | X2 pro 4 |
E150 | CIMREX 12 | E1012 | K10m | n/a | X2 base 5 |
| | | | | X2 pro 4 |
E200 | CIMREX 20 | E1022 | K20m | Adaption Plate K20 | X2 base 5 |
| | | | | X2 pro 4 |
E300 | CIMREX 30 | E1032 | K30m | Adaption Plate K30 | X2 base 5 |
| | | | | X2 pro 4 |
E410 | CIMREX 41 | E1043 (mono) | T40m5 (EOL) | n/a | X2 base 5 |
| | E1041(color) | T405 (EOL) | | X2 pro 4 |
E600 | CIMREX 60 | E1060 (color) | K60m | Adaption Plate K60 | X2 base 7 |
| | E1062 (mono) | | | X2 pro 7 |
E610 | CIMREX 67 | E1063 | T60m5 (EOL) | Adaption Plate T60 | X2 base 7 |
| | | | | X2 pro 7 |
E615 | CIMREX 69 | E1061 | T605 (EOL) | Adaption Plate T60 | X2 base 7 |
| | | | | X2 pro 7 |
E615T | CIMREX 69T | E1061 | T605 (EOL) | Adaption Plate T60 | X2 base 7 |
| | | | | X2 pro 7 |
E700 | CIMREX 70 | E1070 | K60 or K70 | Adaption Plate K70 | X2 base 7 |
| | | | | X2 pro 7 |
E710 | CIMREX 71 | E1071 | T70 | Adaption Plate K70 | X2 base 7 |
| | | | | X2 pro 7 |
E900T | CIMREX 90 | E1100 | K100 | Adaption Plate K100 | X2 base 10 |
| | | | | X2 pro 10 |
| | | | | X2 pro 12 |
E900TD | CIMREX 90D | E1100 | K100 | Adaption Plate K100 | X2 base 10 |
| | | | | X2 pro 10 |
| | | | | X2 pro 12 |
E900VT | n/a | E1100 | K100 | n/a | X2 base 10 |
| | | | | X2 pro 10 |
| | | | | X2 pro 12 |
E910T | CIMREX 91 | E1101 | T100 | Adaption Plate T100 | X2 base 10 |
| | | | | X2 pro 10 |
| | | | | X2 pro 12 |
E910TD | CIMREX 91D | E1101 | T100 | Adaption Plate T100 | X2 base 10 |
| | | | | X2 pro 10 |
| | | | | X2 pro 12 |
n/a | n/a | E1151 | T150 | n/a | X2 pro 15 |
1 The Beijer-built E-series models were branded for Mitsubishi. The CIMREX models were the Beijer-branded versions of the early E-series models. All were discontinued a number of years ago.
2 The E1000 models are upgrades from the older, discontinued E-series models. Historically, the Beijer-built E1000 models were branded for Mitsubishi, but now carry a Beijer brand. The E1000 are now only available from Beijer or an authorized distributor; they are no longer available from Mitsubishi. E1000 programming is based on E-Designer software which can now only be obtained from Beijer.
3 The Beijer-built and branded EXTER models are virtually identical to the E1000 models. EXTER programming is based on Information Designer software. Beijer Technical Support can convert an E-Designer program to an Information Designer program, if required.
4 X2 models are not 100% replacement models for the E1000 or EXTER models. They have different form-factors; there are no X2 Keypad models; all X2 models have color displays. These X2 models are the closest versions to the E1000/EXTER panels. X2 pro models have more memory and faster processors than the X2 base units. iX Developer can import an E-Designer or Information Designer project to run on X2 models, though it may not import 100% of the functionality.
5 Adapter plates enable a smaller footprint EXTER or E1000 HMI to fit in the space occupied by a slightly larger, discontinued Exxx or CIMREX model. Note: Adapter Plates allow most E1000/EXTER models to fit the cut-outs used by the discontinued E-series/CIMREX models.
6 X2 series are Beijer main iX models. See the EOL Notifications for details.
X2 image - Update EBOOT require SD card to be formatted to FAT16/FAT32
Some versions of the system program to X2 require the EBOOT to be updated as well. The EBOOT is included when you create "Recovery SD" from the Image Loader. Please note that the SD card must be formatted to FAT16/FAT32 otherwise the EBOOT will not be updated even though the "Make Recovery SD Card" setting was enabled.
The file system exFAT is not supported when upgrading the EBOOT.
The EBOOT version can be verified in the diagnostics which can be opened from the service menu.
X2 Letter of Volatility
X2 Letter of Volatility
X2 base, X2 pro, X2 marine, X2 control, X2 motion
Battery test summary - X2 base, Y2 base v2, BoX2 base v2, C2 industrial PCs
Battery test summary - X2 base, Y2 base v2, BoX2 base v2, C2 industrial PCs
SDoC Green Passport
SDoC Green Passport
X2 pro, X2 control, X2 motion, X2 marine
RoHS and REACH Declaration of Conformity
Environmental Impact Report X2 pro, X2 marine, X2 control, X2 motion
Environmental Impact Report X2 pro, X2 marine, X2 control, X2 motion
Manufacturer declaration: X2 base v2 UKCA Declaration of Conformity
Manufacturer declaration: X2 base v2 UKCA Declaration of Conformity
CE Manufacturer declaration X2 base v2
CE Manufacturer declaration X2 base v2
CE certificate x2 base 15 v2 HP
CE certificate x2 base 15 v2 HP
KCC certificate X2 base 15 v2 HP
KCC certificate X2 base 15 v2 HP
FCC certificate x2 base 15 v2 HP
FCC certificate x2 base 15 v2 HP
Outline drawing X2 base 15 v2 HP
Outline drawing X2 base 15 v2 HP
Add Tags to Tagmonitor by script
25.03.2019
IX dev. 2.40SP1
X2 control 10 (Should work on all platforms)
Attached sample project adds predefined tags to the TagMonitor object, making it easy to switch between several different sets of tags in the list
Program example iX Developer: Modbus TCP communication between any X2 and BFI-P2/H3.
This is to be found in Smart Engineering, SER0050. Either download the manual further down for SER0050 or the complete Smart Enginnering here.
Program example support:
- Works only towards BFI Frequency inverters BFI-H3 and BFI-P2
- Start and stop
- Change Setfrequency
- Normal-, fast- or coasting-stop
- Inverter Alarm Reset
- Constant overview of Drive Outputs-, Alarm-, Safety-, Running Hours status
- Read and Write of all parameters and data available in the inverter
- Read of Drive type, Input voltage, Power, Frame size, Firmware and serialnumber
- Trend
HMI project created in iX Developer 2.40 SP6.
Program example iX Developer: Modbus RTU communication between any X2 and BFI-E3, BFI-P2 or BFI-H3.
This is to be found in Smart Engineering, SER0051. Either download the manual further down for SER0051 or the complete Smart Enginnering here.
Program example support:
- Works only towards BFI Frequency inverters BFI-E3, BFI-H3 or BFI-P2
- Start and stop
- Change Setfrequency
- Normal-, fast- or coasting-stop
- Inverter Alarm Reset
- Constant overview of Drive Outputs-, Alarm-, Safety-, Running Hours status
- Read and Write of all parameters and data available in the inverter
- Read of Drive type, Input voltage, Power, Frame size, Firmware and serialnumber
- Trend
HMI project created in iX Developer 2.40 SP6.
Program example iX Developer: Modbus TCP communication between any X2 HMI and BFI-E3.
This is to be found in Smart Engineering, SER0060. Either download the manual further down for SER0060 or the complete Smart Enginnering here.
Example shows how X2 Base7 control/monitor up to 63 BFI-E3 in a Modbus TCT network. Functions supported are:
Program example support:
- Works only towards BFI Frequency inverter BFI-E3-MTP
- Start and stop
- Change Setfrequency
- Normal-, fast- or coasting-stop
- Inverter Alarm Reset
- Constant overview of Drive Outputs-, Alarm-, Safety-, Running Hours status
- Read and Write of all parameters and data available in the inverter
- Read of Drive type, Input voltage, Power, Frame size, Firmware and serialnumber
- Trend
HMI project created in iX Developer 2.40 SP6.
iX Templates for E-key and X-Key
Templates for E-key and X-key, created as popups.
Unzip the *.zip file in < C:\Users\Public\Documents\Beijer Electronics AB\iX Developer 2.40 SP4\Screen Templates > and the templates will be available under “Add Screen”>Templates
Connect an action to the buttons, LED-colourfärg/Led-blink as dynamic if used.
Quick start guide - Connect X2 HMI with Nexto PLC, SUEN00414
Ping from IX x2 terminal
27.02.02
IX dev. 2.40 SP4
The attached project sample (X2 control 10), Pings a fixt IP adress every 30 sec, and set\rst a global tag accordingly, to show the status of the connection.
All code is in a scriptmodule, initiated by the "created" event.
The actual Ping syntax is: (returns true\false)
if(Core.Api.Service.ServiceContainerCF.GetService<Neo.ApplicationFramework.Interfaces.INetworkService>().Ping("10.0.0.1", 100))
iX Developer - Top10 Alarm list, based on count and/or duration
You easily implement a Top10 Alarm list in iX.
1. Add a DatabaseViewer control to a screen
2. Add the following script to the screen:
void AlarmScreen_Opened(System.Object sender, System.EventArgs e)
{
DatabaseViewer1.IsControlVisible = false; //Optional, to hide manual controls
}
void btnTop10_Click(System.Object sender, System.EventArgs e){
string sFrom = "1900-01-01"; string sTo = "2999-12-31";
DatabaseViewer1.SendSelectQuery("SELECT [AlarmItemName], [Text], AlarmItemDisplayName,COUNT(*) AS [Count],SUM(strftime('%s',InActiveTime) - strftime('%s',ActiveTime)) AS [Duration (s)] FROM AlarmServer WHERE ActiveTime >= '" + sFrom + "' AND ActiveTime <= '" + sTo + "' GROUP BY [AlarmItemName],AlarmItemDisplayName,[Text] ORDER BY COUNT(*) DESC,[Duration (s)] DESC","Database.db");
}
void btnTop10Duration_Click(System.Object sender, System.EventArgs e){
string sFrom = "1900-01-01"; string sTo = "2999-12-31";
DatabaseViewer1.SendSelectQuery("SELECT [AlarmItemName], [Text], AlarmItemDisplayName,COUNT(*) AS [Count],SUM(strftime('%s',InActiveTime) - strftime('%s',ActiveTime)) AS [Duration (s)] FROM AlarmServer WHERE ActiveTime >= '" + sFrom + "' AND ActiveTime <= '" + sTo + "' GROUP BY [AlarmItemName],AlarmItemDisplayName,[Text] ORDER BY [Duration (s)] DESC, COUNT(*) DESC","Database.db");
}
Quick Start Guide, MELSEC Qnn QJ71E71 Ethernet to X2 series SUEN405
Communication driver in X2: MC Protocol
Quick Start Guide, MELSEC iQ-R Ethernet - X2 series SUEN00406
Communication driver X2: MC Protocol
Quick Start Guide, MELSEC QnUDE Ethernet to X2 series, SUEN00403
Communication driver X2: MC Protocol
Quick Start Guide, MELSEC FX5U/FX5UC Ethernet to X2 series, SUEN00402
iX Developer Reference Manual, MAEN355 rev. B (current version)
X2 base V2 Serial interface mapping
Manual describing the mapping of serial connectors and serial ports on X2 base v2. The serial connectors are labeled A,B,C, while serial ports are named COM1...COM6.
X2 base / pro / extreme / marine / control - Configuration and Image manual , MAEN352 rev B
MAEN352B: describes the X2 series system program V2.2 and later .
This manual replaces MAEN205 rev. G
Installation manuals X2 base 15 v2 HP, MAEN333
MAEN333 X2 base 15 V2 HP
Guidelines for TxA and TxB migration to X2.
Guidelines for TxA and TxB migration to X2.
Environmental report X2 base v2
Environmental report X2 base v2
iX and Allen-Bradley Ethernet CLX
Allen-Bradley ControlLogix and CompactLogix
The E and E1000 series has a driver named Allen-Bradley Ethernet CLX.
This driver is not available in iX Developer. However, that is just the name.
The E1000 variant is actually a limited Ethernet/IP driver, so when converting an E1000 project to iX platform, one can use the Allen-Bradley Ethernet/IP driver instead. This driver also suports newer systems such as the Micro 800, 820 and 850 controllers.
SqlProxy - Connects iX Panels transparently to SQL Server
There's sometimes a need to connect to SQL Server from an iX Panel.
In CE6 based panel, this has been possible using sqlclient.
Nothing similar is however supported in CE8 (most X2 panels).
During the years, we have helped customers creating solutions based on SQL Server connectivity.
There is a need to be able to move such an application to X2 aswell with minimal change of script code.
One solution is "SqlProxy" that is presented in the attached pdf file.
Download:
https://www.beijerelectronics.com/en/support/Help___online?code=4D4C0877-4291-43C8-BA7B-54A456B0B5FE
Install in e.g. C:\Users\Public\SqlProxy to avoid access right issues!
October 16, 2019: The file SqlProxy_191016C.zip contains CURRENT VERSION !
SqlProxy 1.1.0.1. Make sure to use corresponding SqlProxy.exe , tcpServer.dll and scmSqlProxy.Script.cs from the same package!
Supports unicode (e.g. Chinese characters and queries like select * from Customers where Name = N'公司黄页' ). Performance improved.
For best performance, limit the amount of data (number of rows and number of columns) to the minimum necessary with your SQL query. Example: "select top (1) createdTime, columnName3, columnName149 from tableName where columnName1 = 'something' order by createdTime desc"
to get just the few interesting columns from the very latest record where columnName1 = 'something'
Furthermore, for best performance, use StringBuilder when receiving reply from SqlProxy instead of += in the iX demo project. scmSqlProxy.Script_StringBuilder.zip in demo project contains this alternate scmProxy.Script.cs file if needed.
Contact support @beijer.se for additional info!
Remote Access Viewer v1.5.4, for Exter/E1000 - TxA/TxB/TAxx - X2 panels
Remote Access Viewer is a program for remote access and control Exter/E1000 - TxA/TxB/TAxx - X2 panels.
It is possible to access, reflect and control panels
from a PC by using the VNC client program, Remote Access Viewer (freeware),
together with the built-in VNC server (Remote Access function) in the iX
Panels.
NB: Even though the help file suggests another key combination, please note that Ctrl-Alt-Shift-F toggles Full screen mode on / off best, so you Restore from Fullscreen mode with this key combination!
vncviewer.exe_patch.zip contains a patched vncviewer.exe
EDS file for CiX-CAN and X2
EDS_CiX-CAN.zip includes EDS files for the CiX-CAN module:
CiXCANopen.eds General EDS file
CiXCANopen_Default_PDO1.eds EDS file corresponding to Default Slave PDO setting 1
CiXCANopen_Default_PDO2.eds EDS file corresponding to Default Slave PDO setting 2
CiXCANopen_Default_PDO3.eds EDS file corresponding to Default Slave PDO setting 3
CiXCANopen_Default_PDO4.eds EDS file corresponding to Default Slave PDO setting 4
EDS_X2.zip includes EDS files for the internal CAN on X2 (extreme) panels:
X2CANopen.eds General EDS file
X2CANopen_Default_PDO1.eds EDS file corresponding to Default Slave PDO setting 1
X2CANopen_Default_PDO2.eds EDS file corresponding to Default Slave PDO setting 2
X2CANopen_Default_PDO3.eds EDS file corresponding to Default Slave PDO setting 3
X2CANopen_Default_PDO4.eds EDS file corresponding to Default Slave PDO setting 4
X2 series (German)
36-page brochure incl. general and product family descriptions, technical data, iX and WARP software descriptions, migration paths, etc.
X2 brochure (English), BREN631
36 page brochure incl. general and product family descriptions, technical data, iX and acirr+ software descriptions, migration paths, etc. Incl. X2 extreme, X2 pro21 and two-year warranty
X2 base v2 image V2.2 b1041 (Current version)
Related documents:
X2 series Custom Welcome Screen (splash), template
Template file for customising the Welcome Screen, refer to X2 image manual.
Custom Welcome screen is supported on X2 base v2 and X2 pro/marine/control/extreme. Currently only X2 base v2 and X2 extreme support customization using this .cfg file and this require the latest versions of the system programs (X2 base V2 v1.02 b280 | X2 extreme v2.1 b430).
X2 base V2 1.1 (Current version)
X2 base V2 firmware image version 1.1 (b1015).
X2 base v2 (HP) 1.0.2 b280
Firmware image, version 1.0.2 b280, for X2 base v2, Basic and HP. Custom splash template file included in this package.